Vacuum switches apply the vacuum signal to a diaphragm that is opposed by a combination of spring forces. When the signal force is greater than the spring force it reaches its set-point (also called “On” pressure), and the internal mechanism moves and changes the electrical state. When the switch trips, the normally open circuit closes and the normally closed circuit opens. The switch will remain in this state until the vacuum signal moves back to its reset point (also called “Off” pressure). The difference between the “On” and “Off” pressure is defined as the Differential or Hysteresis of the switch.
Unit of Measure
Items
V-5100 Series Subminiature Vacuum Switch

Flush Mount Vacuum Switch 5" Hg 0.1 AMP

V-5100 Series Subminiature Vacuum Switch

Flush Mount Vacuum Switch 5" Hg 3 AMP

V-5100 Series Subminiature Vacuum Switch

Flush Mount Vacuum Switch 5" Hg 5 AMP

V-5100 Series Subminiature Vacuum Switch

Flush Mount Vacuum Switch 5" Hg 10 AMP

V-5100 Series Subminiature Vacuum Switch

Flush Mount Vacuum Switch 5" Hg 25 AMP
Description N/A
  • Our standard vacuum switch line with a variety of electrical ratings available. 10A and .1A are the most common versions and will typically have the shortest lead times. 10A is recommended for direct control of most current drawing devices. The .1A switch selection has gold plated contacts and is recommended for low amperage applications such as PLC and micro controlled interface. Other electrical options are available for specific application requirements.
  • Vacuum switches apply signal pressure to a diaphragm that is opposed by a spring force. When then vacuum signal force is greater (deeper vacuum = more force) than the spring force it reaches its set-point (also called “On” pressure), the internal mechanism moves and changes the electrical state.
  • When the switch trips, the normally open circuit closes and the normally closed circuit opens. The switch will remain in this state until the vacuum signal drops below its reset point (also called “Off” pressure).
  • The difference between the “On” pressure and the “Off” pressure is defined as the Differential or Hysteresis of the switch. This is an important characteristic for applications such as vacuum switch-controlled vacuum pump systems. For instance, the consumption and capacity of the system along with the differential of the switch will determine how often the pump runs.
  • Factory preset options are available. Please contact your salesperson or distributor for specifications and a custom part number.
  • Adjustments can be made to the switch by removing the round cover and turning the flat head screw. Clockwise adjustments will lower the Set point (bring the setpoint closer to atmosphere). Counter clockwise adjustments will raise the setpoint (take the setpoint deeper into vacuum). Adjusting preset switches is not recommended. Do not back out the flat head screw above flush with the body.
Model N/A V-5100
Mounting Style N/A Flush Mount
Port Connection N/A Barb for 1/16" I.D. Tubing
Switch Selection N/A 0.1 AMP N/A 3 AMP N/A 5 AMP N/A 10 AMP N/A 25 AMP
Features N/A
  • Adjustment Cap included to protect adjustment screw
  • Terminal Cap included to protect terminals
  • Laser Engraved date code
  • Subminiature Size
  • Made and tested in the USA
  • Presets available
  • N/A
  • Adjustment Cap included to protect adjustment screw
  • Terminal Cap included to protect terminals
  • Laser Engraved date code
  • Subminiature Size
  • Made and tested in the USA
  • Presets available
  • N/A
  • Adjustment Cap included to protect adjustment screw
  • Terminal Cap included to protect terminals
  • Laser Engraved date code
  • Subminiature Size
  • Made and tested in the USA
  • Presets available
  • N/A
  • Adjustment Cap included to protect adjustment screw
  • Terminal Cap included to protect terminals
  • Laser Engraved date code
  • Subminiature Size
  • Made and tested in the USA
  • Presets available
  • N/A
  • Adjustment Cap included to protect adjustment screw
  • Terminal Cap included to protect terminals
  • Laser Engraved date code
  • Subminiature Size
  • Made and tested in the USA
  • Presets available
  • Materials N/A Housing: Polysulfone
    Diaphragm: Polyurethane
    Spring: Stainless Steel or Music Wire
    UL, CSA N/A 0.1 A, 125 Vac N/A 1/10 HP 250 Vac 3 A 125 Vac, 250 Vac, 277 Vac N/A 1/10 HP 250 Vac 5 A 125 Vac, 250 Vac, 277 Vac N/A 1/2 A 125 Vdc 1/4 A 250 Vdc; 5 A 125 Vac “L” 10 A 1/3 HP 125 Vac, 250 Vac or 277 Vac N/A 1 HP, 125 Vac; 2 HP, 250 Vac 25 A, 277 Vac
    ENEC N/A 1 (0.05) A, 250 Vac N/A N/A N/A 3 (1) A, 250 Vac N/A 5 (2) A, 250 Vac N/A 20 (5) A, 250 Vac
    Additional Information N/A This Design maintains ignition-protected components per UL NCKL2/8 certification for use in refrigeration and air-conditioning ENEC: XX(Y) - XX = max. rated resistive value in amps, and (Y) = max. rated inductive value in amps N/A N/A ENEC: XX(Y) - XX = max. rated resistive value in amps, and (Y) = max. rated inductive value in amps N/A
    • L" = Incandescent lamp rating
    • ENEC: XX(Y) - XX = max. rated resistive value in amps, and (Y) = max. rated inductive value in amps
    "
    N/A ENEC: XX(Y) - XX = max. rated resistive value in amps, and (Y) = max. rated inductive value in amps