Vacuum switches apply the vacuum signal to a diaphragm that is opposed by a combination of spring forces. When the signal force is greater than the spring force it reaches its set-point (also called “On” pressure), and the internal mechanism moves and changes the electrical state. When the switch trips, the normally open circuit closes and the normally closed circuit opens. The switch will remain in this state until the vacuum signal moves back to its reset point (also called “Off” pressure). The difference between the “On” and “Off” pressure is defined as the Differential or Hysteresis of the switch.
Items |
![]() V51005FM.1B Flush Mount Vacuum Switch 5" Hg 0.1 AMP List Price $32.75
|
![]() V51005FMB85.1B Flush Mount Vacuum Switch 5" Hg 0.1 AMP List Price $32.75
|
![]() V51005FM10A Flush Mount Vacuum Switch 5" Hg 10 AMP List Price QUOTE
|
![]() V51005FMB8510A Flush Mount Vacuum Switch 5" Hg 10 AMP List Price QUOTE
|
![]() V51005FM25A Flush Mount Vacuum Switch 5" Hg 25 AMP List Price $26.43
|
|||||
Description |
N/A
|
|||||||||
Model | N/A V-5100 | |||||||||
Mounting Style | N/A Flush Mount | |||||||||
Port Connection | N/A Barb for 1/16" I.D. Tubing | N/A Barb for 1/8" I.D. Tubing | N/A Barb for 1/16" I.D. Tubing | N/A Barb for 1/8" I.D. Tubing | N/A Barb for 1/16" I.D. Tubing | |||||
Switch Selection | N/A 0.1 AMP | N/A 0.1 AMP | N/A 10 AMP | N/A 10 AMP | N/A 25 AMP | |||||
Features |
N/A
|
|||||||||
Materials |
N/A
Housing: Polysulfone Diaphragm: Polyurethane Spring: Stainless Steel or Music Wire |
|||||||||
UL, CSA |
N/A
0.1 A, 125 Vac |
N/A
0.1 A, 125 Vac |
N/A
1/2 A 125 Vdc 1/4 A 250 Vdc; 5 A 125 Vac “L” 10 A 1/3 HP 125 Vac, 250 Vac or 277 Vac |
N/A
1/2 A 125 Vdc 1/4 A 250 Vdc; 5 A 125 Vac “L” 10 A 1/3 HP 125 Vac, 250 Vac or 277 Vac |
N/A
1 HP, 125 Vac; 2 HP, 250 Vac 25 A, 277 Vac |
|||||
ENEC | N/A 1 (0.05) A, 250 Vac | N/A 1 (0.05) A, 250 Vac | N/A 5 (2) A, 250 Vac | N/A 5 (2) A, 250 Vac | N/A 20 (5) A, 250 Vac | |||||
Additional Information |
N/A
This Design maintains ignition-protected components per UL NCKL2/8 certification for use in refrigeration and air-conditioning ENEC: XX(Y) - XX = max. rated resistive value in amps, and (Y) = max. rated inductive value in amps |
N/A
This Design maintains ignition-protected components per UL NCKL2/8 certification for use in refrigeration and air-conditioning ENEC: XX(Y) - XX = max. rated resistive value in amps, and (Y) = max. rated inductive value in amps |
N/A
" |
N/A
" |
N/A
ENEC: XX(Y) - XX = max. rated resistive value in amps, and (Y) = max. rated inductive value in amps |
|||||
Clearance Hole in Panel | N/A | |||||||||
Retaining Nut Included | N/A | |||||||||
|