Print Back

Vacuum switches apply the vacuum signal to a diaphragm that is opposed by a combination of spring forces. When the signal force is greater than the spring force it reaches its set-point (also called “On” pressure), and the internal mechanism moves and changes the electrical state. When the switch trips, the normally open circuit closes and the normally closed circuit opens. The switch will remain in this state until the vacuum signal moves back to its reset point (also called “Off” pressure). The difference between the “On” and “Off” pressure is defined as the Differential or Hysteresis of the switch.

V51005FM.1B.png
Unit of Measure
1 2 

Product Number

Image

Adjustment Range

Mounting Style

Port Connection

Switch Selection

V510010PMB8510A
 
N/A 2 to 10° Hg N/A Panel Mount 1/8-27 NPS N/A Barb for 1/8" I.D. Tubing N/A 10 AMP
V510028PM.1B
 
N/A 3 to 28° Hg N/A Panel Mount 1/8-27 NPS N/A Barb for 1/16" I.D. Tubing N/A 0.1 AMP
V510028PMB85.1B
 
N/A 3 to 28° Hg N/A Panel Mount 1/8-27 NPS N/A Barb for 1/8" I.D. Tubing N/A 0.1 AMP
V510028PM10A
 
N/A 3 to 28° Hg N/A Panel Mount 1/8-27 NPS N/A Barb for 1/16" I.D. Tubing N/A 10 AMP
V510028PMB8510A
 
N/A 3 to 28° Hg N/A Panel Mount 1/8-27 NPS N/A Barb for 1/8" I.D. Tubing N/A 10 AMP
V51005PT.1B
 
N/A 1 to 5° Hg N/A Pipe Thread Mount 1/8-27 NPT N/A Barb for 1/16" I.D. Tubing N/A 0.1 AMP
V51005PTB85.1B
 
N/A 1 to 5° Hg N/A Pipe Thread Mount 1/8-27 NPT N/A Barb for 1/8" I.D. Tubing N/A 0.1 AMP
V51005PT10A
 
N/A 1 to 5° Hg N/A Pipe Thread Mount 1/8-27 NPT N/A Barb for 1/16" I.D. Tubing N/A 10 AMP
V51005PTB8510A
 
N/A 1 to 5° Hg N/A Pipe Thread Mount 1/8-27 NPT N/A Barb for 1/8" I.D. Tubing N/A 10 AMP
V510010PT.1B
 
N/A 2 to 10° Hg N/A Pipe Thread Mount 1/8-27 NPT N/A Barb for 1/16" I.D. Tubing N/A 0.1 AMP
V510010PTB85.1B
 
N/A 2 to 10° Hg N/A Pipe Thread Mount 1/8-27 NPT N/A Barb for 1/8" I.D. Tubing N/A 0.1 AMP
V510010PT10A
 
N/A 2 to 10° Hg N/A Pipe Thread Mount 1/8-27 NPT N/A Barb for 1/16" I.D. Tubing N/A 10 AMP
V510010PTB8510A
 
N/A 2 to 10° Hg N/A Pipe Thread Mount 1/8-27 NPT N/A Barb for 1/8" I.D. Tubing N/A 10 AMP
V510028PT.1B
 
N/A 3 to 28° Hg N/A Pipe Thread Mount 1/8-27 NPT N/A Barb for 1/16" I.D. Tubing N/A 0.1 AMP
V510028PTB85.1B
 
N/A 3 to 28° Hg N/A Pipe Thread Mount 1/8-27 NPT N/A Barb for 1/8" I.D. Tubing N/A 0.1 AMP
V510028PT10A
 
N/A 3 to 28° Hg N/A Pipe Thread Mount 1/8-27 NPT N/A Barb for 1/16" I.D. Tubing N/A 10 AMP
V510028PTB8510A
 
N/A 3 to 28° Hg N/A Pipe Thread Mount 1/8-27 NPT N/A Barb for 1/8" I.D. Tubing N/A 10 AMP
Unit of Measure