Print Back

Vacuum switches apply the vacuum signal to a diaphragm that is opposed by a combination of spring forces. When the signal force is greater than the spring force it reaches its set-point (also called “On” pressure), and the internal mechanism moves and changes the electrical state. When the switch trips, the normally open circuit closes and the normally closed circuit opens. The switch will remain in this state until the vacuum signal moves back to its reset point (also called “Off” pressure). The difference between the “On” and “Off” pressure is defined as the Differential or Hysteresis of the switch.

V-5100 Series Subminiature Vacuum Switch
Unit of Measure
1 2 3 

Product Number

Image

Adjustment Range

Mounting Style

Port Connection

Switch Selection

V51005FM.1B

N/A 1 to 5° Hg N/A Flush Mount N/A Barb for 1/16" I.D. Tubing N/A 0.1 AMP
V51005FMB85.1B

N/A 1 to 5° Hg N/A Flush Mount N/A Barb for 1/8" I.D. Tubing N/A 0.1 AMP
V51005FM10A

N/A 1 to 5° Hg N/A Flush Mount N/A Barb for 1/16" I.D. Tubing N/A 10 AMP
V51005FMB8510A

N/A 1 to 5° Hg N/A Flush Mount N/A Barb for 1/8" I.D. Tubing N/A 10 AMP
V51005FM25A

N/A 1 to 5° Hg N/A Flush Mount N/A Barb for 1/16" I.D. Tubing N/A 25 AMP
V51005FMB8525A

N/A 1 to 5° Hg N/A Flush Mount N/A Barb for 1/8" I.D. Tubing N/A 25 AMP
V510010FM.1B

N/A 2 to 10° Hg N/A Flush Mount N/A Barb for 1/16" I.D. Tubing N/A 0.1 AMP
V510010FMB85.1B

N/A 2 to 10° Hg N/A Flush Mount N/A Barb for 1/8" I.D. Tubing N/A 0.1 AMP
V510010FM10A

N/A 2 to 10° Hg N/A Flush Mount N/A Barb for 1/16" I.D. Tubing N/A 10 AMP
V510010FMB8510A

N/A 2 to 10° Hg N/A Flush Mount N/A Barb for 1/8" I.D. Tubing N/A 10 AMP
V510010FM25A

N/A 2 to 10° Hg N/A Flush Mount N/A Barb for 1/16" I.D. Tubing N/A 25 AMP
V510010FMB8525A

N/A 2 to 10° Hg N/A Flush Mount N/A Barb for 1/8" I.D. Tubing N/A 25 AMP
V510028FM.1B

N/A 3 to 28° Hg N/A Flush Mount N/A Barb for 1/16" I.D. Tubing N/A 0.1 AMP
V510028FMB85.1B

N/A 3 to 28° Hg N/A Flush Mount N/A Barb for 1/8" I.D. Tubing N/A 0.1 AMP
V510028FM10A

N/A 3 to 28° Hg N/A Flush Mount N/A Barb for 1/16" I.D. Tubing N/A 10 AMP
V510028FMB8510A

N/A 3 to 28° Hg N/A Flush Mount N/A Barb for 1/8" I.D. Tubing N/A 10 AMP
V510028FM25A

N/A 3 to 28° Hg N/A Flush Mount N/A Barb for 1/16" I.D. Tubing N/A 25 AMP
V510028FMB8525A

N/A 3 to 28° Hg N/A Flush Mount N/A Barb for 1/8" I.D. Tubing N/A 25 AMP
V51005MM.1B

N/A 1 to 5° Hg N/A Manifold Mount N/A Manifold N/A 0.1 AMP
V51005MM10A

N/A 1 to 5° Hg N/A Manifold Mount N/A Manifold N/A 10 AMP
V51005MM25A

N/A 1 to 5° Hg N/A Manifold Mount N/A Manifold N/A 25 AMP
V510010MM.1B

N/A 2 to 10° Hg N/A Manifold Mount N/A Manifold N/A 0.1 AMP
V510010MM10A

N/A 2 to 10° Hg N/A Manifold Mount N/A Manifold N/A 10 AMP
V510010MM25A

N/A 2 to 10° Hg N/A Manifold Mount N/A Manifold N/A 25 AMP
V510028MM.1B

N/A 3 to 28° Hg N/A Manifold Mount N/A Manifold N/A 0.1 AMP
Unit of Measure
1 2 3