Print Back
Pressure switches apply the signal pressure to a diaphragm that is opposed by a spring force. When the pressure signal force is greater than the spring force it reaches its set-point (also called “On” pressure), and the internal mechanism moves and changes the electrical state. When the switch trips, the normally open circuit closes and the normally closed circuit opens. The switch will remain in this state until the pressure signal drops below its reset point (also called “Off” pressure). The difference between the “On” pressure and the “Off” pressure is defined as the Differential or Hysteresis of the switch.
F-5100 Series Subminiature Pressure Switch
Unit of Measure
 1 2 3 4 5 »  

Product Number

Image

Adjustment Range

Mounting Style

Port Connection

Switch Selection

CAD

F510015FM.1B

N/A 0.5 to 15 PSI N/A Flush Mount N/A Barb for 1/16" I.D. Tubing N/A 0.1 AMP N/A
F510015FM3A

N/A 0.5 to 15 PSI N/A Flush Mount N/A Barb for 1/16" I.D. Tubing N/A 3 AMP N/A
F510015FM5A

N/A 0.5 to 15 PSI N/A Flush Mount N/A Barb for 1/16" I.D. Tubing N/A 5 AMP N/A
F510015FM10A

N/A 0.5 to 15 PSI N/A Flush Mount N/A Barb for 1/16" I.D. Tubing N/A 10 AMP N/A
F510015FM

N/A 0.5 to 15 PSI N/A Flush Mount N/A Barb for 1/16" I.D. Tubing N/A 15 AMP N/A
F510015FM25A

N/A 0.5 to 15 PSI N/A Flush Mount N/A Barb for 1/16" I.D. Tubing N/A 25 AMP N/A
F510015FMB85.1B

N/A 0.5 to 15 PSI N/A Flush Mount N/A Barb for 1/8" I.D. Tubing N/A 0.1 AMP N/A
F510015FMB853A

N/A 0.5 to 15 PSI N/A Flush Mount N/A Barb for 1/8" I.D. Tubing N/A 3 AMP N/A
F510015FMB855A

N/A 0.5 to 15 PSI N/A Flush Mount N/A Barb for 1/8" I.D. Tubing N/A 5 AMP N/A
F510015FMB8510A

N/A 0.5 to 15 PSI N/A Flush Mount N/A Barb for 1/8" I.D. Tubing N/A 10 AMP N/A
F510015FMB85

N/A 0.5 to 15 PSI N/A Flush Mount N/A Barb for 1/8" I.D. Tubing N/A 15 AMP N/A
F510015FMB8525A

N/A 0.5 to 15 PSI N/A Flush Mount N/A Barb for 1/8" I.D. Tubing N/A 25 AMP N/A
F510015PM.1B

N/A 0.5 to 15 PSI N/A Panel Mount 1/8-27 NPS N/A Barb for 1/16" I.D. Tubing N/A 0.1 AMP N/A
F510015PM3A

N/A 0.5 to 15 PSI N/A Panel Mount 1/8-27 NPS N/A Barb for 1/16" I.D. Tubing N/A 3 AMP N/A
F510015PM5A

N/A 0.5 to 15 PSI N/A Panel Mount 1/8-27 NPS N/A Barb for 1/16" I.D. Tubing N/A 5 AMP N/A
F510015PM10A

N/A 0.5 to 15 PSI N/A Panel Mount 1/8-27 NPS N/A Barb for 1/16" I.D. Tubing N/A 10 AMP N/A
F510015PM

N/A 0.5 to 15 PSI N/A Panel Mount 1/8-27 NPS N/A Barb for 1/16" I.D. Tubing N/A 15 AMP N/A
F510015PM25A

N/A 0.5 to 15 PSI N/A Panel Mount 1/8-27 NPS N/A Barb for 1/16" I.D. Tubing N/A 25 AMP N/A
F510015PMB85.1B

N/A 0.5 to 15 PSI N/A Panel Mount 1/8-27 NPS N/A Barb for 1/8" I.D. Tubing N/A 0.1 AMP N/A
F510015PMB853A

N/A 0.5 to 15 PSI N/A Panel Mount 1/8-27 NPS N/A Barb for 1/8" I.D. Tubing N/A 3 AMP N/A
F510015PMB855A

N/A 0.5 to 15 PSI N/A Panel Mount 1/8-27 NPS N/A Barb for 1/8" I.D. Tubing N/A 5 AMP N/A
F510015PMB8510A

N/A 0.5 to 15 PSI N/A Panel Mount 1/8-27 NPS N/A Barb for 1/8" I.D. Tubing N/A 10 AMP N/A
F510015PMB85

N/A 0.5 to 15 PSI N/A Panel Mount 1/8-27 NPS N/A Barb for 1/8" I.D. Tubing N/A 15 AMP N/A
F510015PMB8525A

N/A 0.5 to 15 PSI N/A Panel Mount 1/8-27 NPS N/A Barb for 1/8" I.D. Tubing N/A 25 AMP N/A
F510015MM.1B

N/A 0.5 to 15 PSI N/A Manifold Mount N/A Manifold N/A 0.1 AMP N/A
Unit of Measure